SKU: Dahua Cat 6 Pure Copper 100 Meters Roll
Dahua Cat6 Cable Pure Copper
Rs. 6,500
DH-PFM922I-6UN-C-100 UTP CAT6 Cable- 100 Meters Cat6 Cable For Networking & CCTV Installations.
Network cables are the most commonly used transmission mediums in generic cabling system. It is usually composed of 4 pairs of twisted wires, and is generally applied in system cabling within 100 meters.
- UTP CAT6 Cable
- 100 m (328 ft)/carton UTP CAT6, power over Ethernet, compatible with one cable
- Manufacturing excellence
- Customized PVC outer sheath; CE CPR Eca flame retardant class certified
- Top-notch Quality Commitment for 10 Years
* 13% Exclusive.
QUANTITY:
DH-PFM922I-6UN-C-100 UTP CAT6 Cable- 100 Meters Cat6 Cable
Material | Oxygen free copper (99.97% purity) |
Diameter | 0.57 mm ± 0.01 mm (0.0224"±0.0004") |
American Wire Gauge | 23AWG |
Material | HDPE |
Min. Average Thickness | 0.21 mm (0.0083") |
Diameter | 1.0 mm ± 0.1 mm (0.0394"±0.004") |
Color (4 Pairs) | Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown |
Material | PE |
Specification | Translucent 4.5 mm × 0.4 mm (0.1772" ± 0.0157") |
Material | Polyester |
Specification | 500D |
Material | PVC |
Min. Average Thickness | 0.5 mm (0.0197") |
Diameter | 6.3 mm ± 0.3 mm (0.2480"±0.0118") |
Color | White |
Max. DC Resistance of a Single Conductor | 7.5Ω/100 m |
Min. Insulation Resistance | 5000MΩ·km |
Max. DC Resistance Unbalance | 2% (pair intra), 4% (pairs inter) |
Dielectric Strength | No breakdown with 1kV DC for 1 min |
Characteristic Impedance | 100 Ω ± 15 Ω |
Near End Cross Talk | ≥39.30 dB/100 m @250 MHz |
Max. Attenuation | 33 dB/100 m @250 MHz |
Return Loss | ≥17.3 dB/100 m @250 MHz |
Tensile Strength | Sheath≥9 MPa, insulation≥16 MPa |
Elongation at Break | Sheath≥100%, insulation≥100% |
Installation Bending Radius | >8 times of outer cable diameter |
Conductor Elongation at Break | ≥8% |
Shrinkage of Insulation | ≤5% |
Color Migration Resistance of Insulation | No migration |
Sheath Tensile Strength and Elongation at Break after Aging | ≥6.3 MPa, ≥100% |
Low Temperature Bending Test | No cracking after the test |
Heat Shock Test | No cracking after the test |
Operating Temperature | –20°C to +60°C (–4°F to 140°F) |
Installation Temperature | 0°C to +50°C (32°F to 122°F) |
Storage Temperature and Humidity | –10°C to +40°C (14°F to 104°F), <60% (RH) |
Vertical Fire Propagation Test | Comply with IEC 60332-1-2 |
Cable Length | 100.0 m (328.08 ft) ±1 m (3.28 ft) |
Inner Carton Dimensions | 286 mm × 119 mm × 289 mm (11.26" × 4.69" × 11.38") (L × W × H) |
Net Weight | 4.2 kg ± 0.3 kg (9.26 lb±0.66 lb) |
Gross Weight | 4.5 kg ± 0.3 kg (9.92 lb±0.66 lb) |
Packaging Dimensions | 595 mm × 310 mm × 270 mm (23.43" × 12.20" × 10.62") (L × W × H) |
Packaging Method | 100 m/carton, 4 inner cartons in one package |
Executive Standards | ISO/IEC 11801-1-2017, IEC 61156-5-2009 |
Certification | CPR Eca |